Para Laboran, Analis Laboratorium lebih-lebih Manager atau Kepala Laboratorium pastinya mengenal UV/Vis Spectro photo meter, namun ini akan kami tampilkan barangkali bisa untuk mereiview dan atau ada yang sedang mencari UV/Vis Spectrophotometer Single Beam silahkan di baca, akan tetapi artikel ini saya sajikandalam bahasa Inggris, bagiyang membutuhakn keterangan silahkan hubungi email kami membagiilmuoehsunarta@gmail.com atau sun_elarta@yahoo.com atau apabila inign WA ke nomor 082137320434 berikut artikelnya :
FEATURES :
· Data output : Data can be exported to U disk ( USB output )
· Pre-aligened design ensures the user can be change lamps conveniently.
· With SiO2 Coating optical mirror , reducing the pollution from outsid fully.
· Ptint Port : Instrument can connect PCL printer to printing A4 paper ( USB port )
· Imported & Environmental Deuterium lamp, preventing from Ozone inhalation
· Real –Time Monitoring the Life time of Deuterium lamp and Tungsten Lamp with advance d system
· Large LCD screen ( 480*272 )with 65 thousand true color and support U disk data saving
· Wavelength calibration , wavelength setting , Change lamp source and dark current calibration automatically.
· Adopted high Class grating with wholly hermetic light path design, to insure the instrument has the super stray light.
· With GLP self check function, check the wave length accuracy and Phtometry accuracy, can provide test report and power off protection.
BASIC FUNTION :
· Photometry :
Test Abs, Transmittance and Energy by Fixed wavelength.
· Quantitaive :
Liniar fit and Linear fit through Zero two models
a. Coefficient, Standard sample input and standard sample read three modes to establish standard curve
b. Establish A=K1*C+K0, can search original data graph curve , parameter setting.
c. Can save 240 groups curve . can test 240 data in each curve
d. Double wavelength , triple wavelength test function.
· Kinetics :
Used for time course scanning or reaction rate calculation ΔA/t, can search All data.
· Multi Wavelength :
Can test Transmittance and Abs with 8 different wavelength at most
· Scanning:
User can set the scan range from 190 nm to 1100 nm to test the max. Abs.peak value can do derivation, arithmetical operations to the graph.
· Biology
6 Methods : DNA / protein, UV, Lowry,BCA,CBB,and Biuret.
TECHNICAL PARAMETERS :
Optical System : Single Beam , Grating 1200 lines/mm
Wavelength range : 190 ~1100 nm
Spectral Bandwidth : 2 nm
Wavelength Accuracy : ± 0.5 nm
Wavelength Repeatability : ≤ 0.2 nm
Photometric Accuracy : ± 0.002A ( 0~0.5 Abs), ±0.004A ( 0.5 ~ 1.0 Abs ),±0.5% T(0~100%T )
Photometric Repeatability : 0.001Abs(0~0.5Abs), 0.002 Abs(0.5 ~1.0 Abs),≤ 0.2% T(0 ~100 % T )
Stray Light : ≤ 0.04 % T@360nm , 220 nm
Stability : ± 0.001A/h @ 500 nm
Baseline Flatness : ± 0.002A
Noise : 0.0005Abs @500 nm
Display : 480*272 65 thousand true color TFTLCD
Photometric mode : T , A , C , E
Photometric range : 0 ~ 200 % T, - 0.301 ~ 3.0 A
Detector : Silicone Photodiode
Light source : Deuterium Lamp , Tungsten Lamp
Input : Membrane Keypad
Output : USB Print and dataoutput, Conect PC
Standard Accerories : 10 mm glass Cuvette 4 units
10 mm quartz cuvette 2 units
Power Suplay : 110/220 V ± 10%, 60/50 Hz
Packing Size ( W*D*H)mm: 620*500*370
Gross Weight : 18 Kg